1. The aerodynamic model is used for fluid simulation, which greatly improves the design accuracy of the fan, and the efficiency of the whole machine is high.
2. The wear-resistant part of the impeller adopts surfacing welding and wear-resistant treatment to meet the airtightness requirements of the desulfurization system.
3. The key operating components are selected from well-known brands at home and abroad, which effectively improves the operation reliability of the fan products.
Type of fan | medium | temperature ℃) | Air Capacity (m³/h) |
Total Pressure (Pa) |
Rotation Speed (r/min) |
Power (kW) |
model |
Ring cooling fan | The air | 20 | 200000~500000 | 2500~4500 | 730~960 | 400~800 | 4-73 |
Pellet dust removal fan | The air | 80~120 | 10000~200000 | 3000~5000 | 730~960 | 400~800 | 4-73 |
Sintering dust removal fan | The air | 80~120 | 800000~1200000 | 3000~5000 | 730~960 | 1400~2500 | 5-2X51 |
Coking plant desulfurization fan | The air | 200~300 | 400000~600000 | 4000~7000 | 730~960 | 1000~2000 | 6-2X39 |
Secondary converter dust removal fan | Flue gas | 80~150 | 800000~1200000 | 5000~8000 | 730~960 | 1250~2000 | 4-2X73 |