Air Capacity: 9890 – 709000м³ /h;
Total Pressure: 1638 – 9828Pа;
Power:90-2000kw;
Temperature: 20-600℃; 

We're here to help: Easy ways to get the answers you need.

SEND EMAIL SEND INQUIRY
Share with:
Description
Cement industry is one of industries which SIMO BLOWER is best at, SIMO BLOWER has lots of fan products for cement production line: air supply of rotary kiln fan, materials conveying fan, cooling of grate cooler fan, cooling of Rotary kiln cylinder fan, high temperature air induced fan and dust removing fan, etc, which can satisfy various applications of cement production line, such as air supply of rotary kiln, materials conveying, cooling of grate cooler, cooling of Rotary kiln cylinder, high temperature air induced and dust removing, etc. In the rugged environment of extreme high temperature and heavy wear, SIMO BLOWER’s cement fans can work reliably, and service life can be extended to 3 to 5 times.
production Craft

 

Specification

 

 

Type of fan picture medium temperature ℃)  Air Capacity(m³/h) Total Pressure(Pa) Rotation Speed(r/min) Power(kW)
High-Temperature  Preheater Fan HighTemp gas 220~350 300000~600000 6000~9000 960 1600~3000
Raw Mill Fan dusty gas 80~120 300000~600000 6000~12000 960 1000~2000
Preheater Exhaust Fan dusty gas 100~150 300000~700000 2000~4000 730~960 400~900
Coal Grinding Exhaust Fan dusty gas 60~150 60000~200000 8000~12000 960~1450 200~500
Kiln Head Exhaust Fan dusty gas 100~150 300000~700000 3000~5000 730~960 400~900
Grate Cooler Fan The air 20 20000~50000 6000~13000 1450~2900 75~315
Chute Fan The air 20 500~2000 4000~7000 2900 4~11

process fan
  

Raw Mill Fans:

Raw mill fan in cement industry carries gas and raw meal. The pressure drop in raw mill fan is very high. If a vertical roller mill is used for raw grinding in cement industry then a large raw mill fan is installed. Usually cement industries use centrifugal fans to carry out this process.

Induced Draft Fans:

Induced draft fans supply the necessary air for the combustion of fuel in the kiln of a cement. It is considered as the ‘lung’ of the clinker burning system. Without the aid of induced draft fan, the gas flow and combustion of the fuel are not possible, calciner cannot happen, the gas from combustion and decomposition cannot be taken out of the system, and the heat exchange between cold raw meal and hot gas cannot happen. Fans for induced draft are radial, forward curved or backward inclined centrifugal fans. If the induced fans are not properly manufactured and operated, it may effect the power consumption of the cement industry.

Grate Cooler Fan:

Cement industry uses large number of grate cooler fan usually between 5 to 15 in one clinker line based on the kiln capacity.  grate cooler fan are used to blow cold air to the cooler and to cool the clinker from 1500oC to 100oC. Cooling kiln protects equipment and facilitates quenching the clinker to ensure the important forms of minerals like C3S, C2S, C3A, C4AF stay in it, so that proper clinker quality is maintained. Improper design of cooling fans can lead to poor clinker quality, high power consumption and even damage of the conveying system.

Raw mill exhaust fans:

Raw mill exhaust fans or stack fans are also called as de-dusting fans. In cement industry raw mill exhaust fans handle 2.2 ton of exhaust gases for the production of 1 ton of clinker. Raw mill exhaust fans are operated with very adverse situations because the fan handles mainly gases such as CO2, N2, NOx and Sox along with some dust particles.

Coal Grinding Exhaust Fan:

In cement industry coal grinding exhaust fan are used to supply required air for burning coal and remove the exhaust gases produced after burning. These fans help in effective burning of coal inside the mill. For a large clinker line there are usually 2 or 3 cement mills.
 
In addition to these key process fans, cement industry also has many non-process fans. These fans work all together with bag filters, for the de-dusting of various conveying systems.